Key result
Routine chest CT tricuspid annular diameter ≥41 mm predicts moderate-to-severe TR with ~97% specificity.
Why the study?
Does measurement of tricuspid annular diameter on routine chest CT predict moderate to severe tricuspid regurgitation?
Observational
Does measurement of tricuspid annular diameter on routine chest CT predict moderate to severe tricuspid regurgitation?
Answers are grounded in this paper and cite their sources.
Measurement of the tricuspid annular diameter on routine chest CT can effectively screen for significant tricuspid regurgitation, identifying patients who warrant further echocardiographic evaluation.
Using a cut point of ≥ 41 mm, measurement of the tricuspid valve annulus on routine CT of the chest can predict moderate to severe TR with a specificity of 96.5% and sensitivity of 75.7%. Measurements below threshold had a 95.5% negative predictive value. Tricuspid annular diameter can be measured on routine contrast-enhanced CT images of the chest, and, when above threshold, further evaluation with echocardiography should be recommended.
No takes yet. Share an insight, caveat, or question.
Hassani et al. (2019) conducted an observational in Tricuspid Regurgitation. Tricuspid annular diameter measurement on routine chest CT was evaluated on Moderate to severe tricuspid regurgitation (Sensitivity 75.7%, Specificity 96.5%). Tricuspid annular diameter measurement ≥ 41 mm on routine chest CT predicted moderate to severe tricuspid regurgitation with a specificity of 96.5% and sensitivity of 75.7%.
Synapse has enriched 10 related papers. Consider them for comparative context: