Key result
Robotic beating-heart ASD repair links to shorter operative and bypass times versus arrested-heart repair.
Why the study?
Does totally robotic ASD repair on a beating heart compared to an arrested heart reduce operative times and maintain safety in patients with secundum-type ASD?
Cohort (n=160)
No
Does totally robotic ASD repair on a beating heart compared to an arrested heart reduce operative times and maintain safety in patients with secundum-type ASD?
Totally robotic ASD repair is safe and effective, with the beating-heart approach offering significantly shorter operative and bypass times compared to the arrested-heart approach.
Answers are grounded in this paper and cite their sources.
May reduce operative times in robotic ASD repair; hypothesis-generating and requires randomized confirmation before clinical adoption.
OBJECTIVES: Robotic technology has been applied to atrial septal defect (ASD) repair for more than 10 years, but the number of cases reported is limited and results of long-term follow-up are not clear. This study reports on a large group of patients who underwent totally robotic ASD repair on an arrested or beating heart at a single institution with a 7-year follow-up. METHODS: From 2007 to 2013, 160 patients (median age, 36 years; range, 11-66 years) at our centre underwent selective repair of secundum-type ASD using the da Vinci robotic system. The first 54 cases were performed on an arrested heart (arrested-heart group, n = 54) and the remainder on a beating heart (beating-heart group, n = 106). The mean diameter of defects was 2.9 cm (range, 1.1-4.1 cm). Cardiopulmonary bypass was achieved via cannulation of the femoral vessels and the right internal jugular vein. Blood cardioplegic arrest was induced using a transthoracic Chitwood clamp in the arrested-heart group. With the assistance of a robotic surgical system, atrial septal defect repairs were performed with or without tricuspid valvuloplasty via three 8-mm ports, a camera port and a working port in the right chest. Transoesophageal echocardiography was used to evaluate surgical results and follow-up. RESULTS: Complete ASD closure was verified by intraoperative transoesophageal echocardiography in all patients. None of the procedures was converted to an alternate technique and there were no major complications. There were significant learning curves for cross-clamp time, operative duration and cardiopulmonary bypass time. The beating-heart group had significantly shorter operative and cardiopulmonary bypass durations than the arrested-heart group (P = 0.000). The two groups had similar durations of mechanical ventilation and intensive care unit and hospital stays, and similar drainage volumes. During the 39 ± 21 months of follow-up, no patient required reoperation because of a residual shunt or tricuspid valve regurgitation. CONCLUSIONS: ASD can be performed safely and effectively on an arrested or beating heart with the assistance of robotic technology. This totally endoscopic approach represents an option for patients seeking a reliable, minimally invasive ASD repair with an excellent long-term result.
No takes yet. Share an insight, caveat, or question.
Xiao et al. (2014) conducted a cohort in Secundum-type atrial septal defect (n=160). Totally robotic ASD repair on a beating heart vs. Totally robotic ASD repair on an arrested heart was evaluated on Operative and cardiopulmonary bypass durations (p=0.000). Totally robotic atrial septal defect repair on a beating heart resulted in significantly shorter operative and cardiopulmonary bypass durations compared to an arrested heart approach (P=0.000).
Synapse has enriched 10 related papers. Consider them for comparative context: