Key result
Totally thoracoscopic mitral valve plasty achieves ~98% repair success at 1 year with low mortality.
Why the study?
The feasibility, safety, and effectiveness of a totally thoracoscopic minimally invasive approach for mitral valve disease performed by an experienced operator required evaluation.
Is two-incision totally thoracoscopic mitral valve plasty feasible, safe, and effective regarding short-term adverse events and 1-year valve repair success in patients with mitral valve disease?
Cohort (n=96)
No
Is two-incision totally thoracoscopic mitral valve plasty feasible, safe, and effective regarding short-term adverse events and 1-year valve repair success in patients with mitral valve disease?
Two-port totally thoracoscopic mitral valve repair performed by an experienced operator demonstrates high 1-year durability (97.9% repair success) and low perioperative morbidity without requiring conversion to median sternotomy.
Answers are grounded in this paper and cite their sources.
May support experienced-operator use of thoracoscopic mitral plasty; leaves open need for randomized trials on generalizability and durability.
INTRODUCTION: The totally thoracoscopic approach for mitral valve (MV) disease is a minimally invasive method. We investigated the procedure's feasibility, safety and effectiveness when it was performed by an experienced operator. METHODS: We retrospectively analysed 96 consecutive patients with MV disease treated between March 2016 and November 2019 by minimally invasive procedures. The procedures were performed on a femoral artery-vein bypass through two ports, including a main operation port and a thoracoscopic port. The clinical data of patients were collected, including preoperative cardiac function, operative data, postoperative complications, and follow-up. RESULTS: A total of 96 patients (57 male patients; average age, 49.7±14.5 years; left ventricular ejection fraction, 65.6±7.7%) were enrolled in this study. No intraoperative conversion incision or death occurred. The cardiopulmonary bypass and aortic cross-clamp times were 163.8±50.6 minutes and 119.7±38.9 minutes, respectively. Postoperative chest tube drainage in the first 24 hours was 232.8±108.1 ml. The ventilation time and length of intensive care unit stay were 13.2±6.2 hours and 2.9±2.2 days, respectively. One patient died of disseminated intravascular coagulation and prosthesis thrombosis 3 days after the operation, fearing anticoagulant-related hemorrhage. The overall success rate of valve repair during 1-year follow-up was 97.9%. CONCLUSION: The totally thoracoscopic procedure on mitral valves by an experienced surgeon is technically feasible, safe, effective and worthy of widespread adoption in clinical practice.
No takes yet. Share an insight, caveat, or question.
Cheng et al. (2022) conducted a cohort in Mitral valve disease (n=96). Two-incision totally thoracoscopic mitral valve plasty (MVP) was evaluated on 1-year overall success rate of valve repair. Totally thoracoscopic mitral valve plasty achieved a 97.9% valve repair success rate at 1-year follow-up with 0% intraoperative conversion to sternotomy and 1.0% in-hospital mortality.
Synapse has enriched 10 related papers. Consider them for comparative context: