Key result
Electrical transmission enables simultaneous recording of mechanical contractions and ECG in isolated rat hearts.
The study provides a simple methodological approach for recording mechanical contractions and electrocardiograms in isolated rat hearts.
Facilitates integrated assessments in isolated rat hearts; leaves open translation to other models or in vivo use.
A simple method is described by which it is possible to record the mechanical phenomena of the isoloated rats’ heart by electrical transmission. If neccessary the electrocardiagram can be recorded simultaneaously.
No takes yet. Share an insight, caveat, or question.
Meyler et al. (1958) studied this question. An electrical transmission method enables the simultaneous recording of mechanical contractions and the electrocardiogram in the isolated rat heart.