Key result
ViV-TAVR yields similar 30-day mortality to redo SAVR for failed bioprosthetic aortic valves.
Why the study?
Does transcatheter aortic valve-in-valve replacement improve outcomes compared to redo aortic valve replacement in patients with a degenerative bioprosthetic aortic valve?
Systematic Review
Does transcatheter aortic valve-in-valve replacement improve outcomes compared to redo aortic valve replacement in patients with a degenerative bioprosthetic aortic valve?
Transcatheter aortic valve-in-valve replacement and redo aortic valve replacement are complementary approaches, with viv-TAVR being clinically effective in the short term for selected high-risk patients with failed bioprosthetic valves.
No clear superiority of viv-TAVR over rAVR; leaves open the need for randomized trials to guide valve reintervention.
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether transcatheter aortic valve-in-valve replacement (viv-TAVR) or redo aortic valve replacement (rAVR) is the best strategy in a patient with a degenerative bioprosthetic aortic valve. Altogether, 162 papers were found using the reported search, of which 12 represented the best evidence to answer the question. The authors, journal, date, country of publication, patient group, study type, outcomes and results of papers are tabulated. The results of the studies provided interesting results. All the studies are retrospective. Four papers reported the results of redo aortic valve replacement in patients with failed aortic bioprosthetic valve, six papers demonstrated their results with transcatheter aortic valve-in-valve replacement for the same indication and two papers reported their propensity-matched analysis of outcomes between viv-TAVR and rAVR in patients with previous cardiac surgery. Thirty-day mortality for rAVR was 2.3-15.5% and 0-17% for viv-TAVR. For rAVR, survival rate at 30 days was 83.6%, 76.1% at 1 year, 70.8% at 3 years, at 51.3-66% at 5 years, 61% at 8 years and 61.5% at 10 years. For viv-TAVR, the overall Kaplan-Meier survival rate at 1 year was 83.2%. After viv-TAVR at 1 year, 86.2% of surviving patients were at New York Heart Association (NYHA) class I/II. The complications after rAVR were stroke (4.6-5.8%), reoperation for bleeding (6.9-9.7%), low-cardiac output syndrome (9.9%) whereas complications after viv-TAVR at 30 days were major stroke (1.7%), aortic regurgitation of at least moderate degree (25%), new permanent pacemaker implantation rate (0-11%), ostial coronary obstruction (2%), need for implantation of a second device (5.7%) and major vascular complications (9.2%). It is noteworthy to mention that there is a valve-in-valve application that provides information to surgeons for choosing the correct size of the TAVR valve. Transcatheter aortic valve-in-valve procedures are clinically effective, at least in the short term, and could be an acceptable approach in selected high-risk patients with degenerative bioprosthetic valves. Redo AVR achieves acceptable medium and long-term results. Both techniques could be seen as complementary approaches for high-risk patients.
No takes yet. Share an insight, caveat, or question.
Tourmousoglou et al. (2015) conducted a systematic review in Degenerative bioprosthetic aortic valve. Transcatheter aortic valve-in-valve replacement (viv-TAVR) vs. Redo aortic valve replacement (rAVR) was evaluated on 30-day mortality. In patients with a failed bioprosthetic aortic valve, 30-day mortality was 0-17% for valve-in-valve TAVR and 2.3-15.5% for redo surgical aortic valve replacement across 12 retrospective studies.