Answers are grounded in this paper and cite their sources.
In this work, two common failure modes of nano-electro-mechanical (NEM) relays: (1) electrical breakdown and (2) stiction due to secondary pull-in were analyzed. These effects are dominant when dimensions of the device are scaled to the sub-micrometer scale. Like MEMS devices, design adjustments, such as introduction of dimples, cannot provide a solution. The geometrical parameters and working environment drive directly the occurrence of these failure modes. The beam length is the key parameter in driving the electrical breakdown while the distance of the gate to the drain, the beam thickness, and the actuation gap set the limits for secondary pull-in voltage. The analysis shows that these failure modes could be mitigated and a physical parameters design space could be identified to achieve NEM devices for high speed operation.
No takes yet. Share an insight, caveat, or question.
Ramezani et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: