Key result
Percutaneous occlusion with multiple Amplatzer plugs treats severe Starr-Edwards mitral paravalvular leak in high-risk patient.
Percutaneous paravalvular leak occlusion using Amplatzer Vascular Plugs can be performed as an alternative to surgical re-valving in high-risk patients with Starr-Edwards mitral valve leaks.
Answers are grounded in this paper and cite their sources.
May be considered for high-risk Starr-Edwards paravalvular leaks; extends case experience but leaves open safety and durability data.
: A 56-year-old patient was referred because of refractory heart failure and mild haemolysis caused by multiple, severe paravalvular leaks of a Starr-Edwards valve implanted in mitral position 23 years before. Owing to perceived high risk of surgical re-valving, percutaneous paravalvular leak occlusion was performed by implantation of multiple, simultaneously deployed Amplatzer Vascular Plugs.
No takes yet. Share an insight, caveat, or question.
Santoro et al. (2014) studied this question. Percutaneous paravalvular leak occlusion using multiple Amplatzer Vascular Plugs was performed to treat severe leaks of a Starr-Edwards mitral valve in a high-risk patient.