Key result
Temporary pacing catheter during TAVI inadvertently perforates the interventricular septum and captures the LBB.
This case highlights a rare complication of temporary pacing during TAVI where septal perforation led to left bundle branch capture.
Answers are grounded in this paper and cite their sources.
Alerts to rare septal perforation risk with TAVI pacing; leaves open whether this extends to intentional conduction capture.
This case report describes the first occurrence of capture of the left bundle branch by a temporary pacing catheter that inadvertently perforated the interventricular septum during a transcatheter aortic valve implantation.
No takes yet. Share an insight, caveat, or question.
Mondal et al. (2025) studied this question. A temporary pacing catheter used during transcatheter aortic valve implantation inadvertently perforated the interventricular septum and captured the left bundle branch.