Key result
Intramyocardial electrograms achieve 100% sensitivity for detecting moderate cardiac allograft rejection in a canine model.
Why the study?
Does intramyocardial electrogram recording accurately detect cardiac allograft rejection compared to histology in a canine model?
Does intramyocardial electrogram recording accurately detect cardiac allograft rejection compared to histology in a canine model?
Answers are grounded in this paper and cite their sources.
Recording multiple, preferably bipolar, intramyocardial electrogram leads enhances the diagnostic reliability of detecting moderate cardiac allograft rejection.
The registration of intramyocardial ECG amplitudes (IMEG) is a non-invasive diagnostic method of monitoring cardiac allograft rejection. In order to detect possible sources of error IMEG signals were recorded in heterotopic neck hearts in ten beagle dogs. Immunosuppression was based on cyclosporin A. The rejection process was followed by IMEG registrations as well as by serial myocardial biopsies. Intramyocardial electrogram recordings were made via three unipolar and three bipolar leads obtained from screw-in electrodes in both ventricles and the apex of the allograft. A 10% voltage drop was used as an indicator of rejection. In four dogs, the first rejection episode was treated with methyl-prednisolone and the therapy's success was monitored by IMEG and repeat biopsy. At autopsy the histology of each electrode circumference was correlated with the corresponding IMEG. The average sensitivity of a single lead was not acceptable (unipolar: 28%, bipolar: 47%). When the voltages of different leads were summed up the sensitivity rose to 43% (3 x unipolar), 85% (3 x bipolar) and 100% (all leads). During rejection therapy the IMEG recovered within 24-48 h. We conclude that in moderate allograft rejection (grade 2/3a ISHT classification), the rejection-related changes of intramyocardial ECG voltage amplitude (IMEG) seem to follow a "focal pattern" similar to the histology. Therefore the recording of several, preferably bipolar, electrode configurations appears to enhance adequate diagnostic reliability.
No takes yet. Share an insight, caveat, or question.
Grauhan et al. (1993) studied Cardiac allograft rejection (n=10). Intramyocardial electrogram recordings (IMEG) vs. Serial myocardial biopsies was evaluated on Sensitivity for detecting allograft rejection. Intramyocardial electrogram recordings using a combination of unipolar and bipolar leads achieved 100% sensitivity for detecting moderate cardiac allograft rejection in a canine model.