Answers are grounded in this paper and cite their sources.
For the determination of lactose in milk, "Official Methods" of the A.O.A.C. (1) recognizes a polarimetrie method (Double Dilution) and a copper reduction method (Munson-Walker).With sweetened condensed milk the Munson-Walker method is specified for lactose, while a polarimetric method, requiring readin~ before and after hydrolysis, is the only procedure mentioned for sucrose.No sugar methods are included for such products as cream, ice cream, and dry milk.White (18) has developed a procedure based on the Munson-Walker technique which can be used for lactose and sucrose when present together.This method corrects for certain irregularities in the unmodified Munson-Walker method and has been found more accurate and convenient than "Official Methods" for sweetened condensed milk (13, 10).At best, the recognized methods for lactose and sucrose in dairy products are tedious, lengthy, or require specialized equipment and for this reason sucrose determinations often are avoided.Colorimetric methods for certain carbohydrates, based on the reduction of picric acid, have been developed and used for many years, particularly for glucose in blood and urine (2, 5, 6, 9, 13, 15), but later for carbohydrates in plant materials (16,17,19) and for lactose in milk (3, 10, 12) and other dairy products (3).These methods have proven simpler than the official ones and on the whole quite satisfactory.Most of them, however, were evolved using visual eolorimeters (less sensitive and less accurate than present photoelectric instruments) and in many cases the color development was not strictly proportional to the concentration of sugars, thereby necessitating correction factors, standard curves or standard colors close in color density to the unknowns.hi the belief that a satisfactory eoIorimetric technique, based on the reduction of picric acid, for the simultaneous determination of lactose and sucrose in dairy products would be a very useful tool in dairy products control and in dairy products research, the study reported here was undertaken. EQUIPMENT AND METHODSA Klett-Summerson photoelectric colorimeter was used for all color comparisons, employing a no.52 filter (520 m~) which was found to be slightly more sensitive than the no.54 recommended by the maker of the instrument for picric
No takes yet. Share an insight, caveat, or question.
perry et al. (1950) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: