Key result
Partial tricuspid homograft replacement yields ~83% survival over two decades with durable freedom from reoperation.
Why the study?
There is limited consensus on the optimal surgical strategy for severe tricuspid valve pathology.
Does partial replacement of the tricuspid valve using a tricuspid homograft provide durable long-term outcomes in patients with severe tricuspid valve pathology?
Cohort (n=14)
No
Does partial replacement of the tricuspid valve using a tricuspid homograft provide durable long-term outcomes in patients with severe tricuspid valve pathology?
Partial replacement of the tricuspid valve using a tricuspid homograft demonstrates durable long-term survival and freedom from reoperation over a median 17-year follow-up.
Durable 20-year outcomes in this cohort support selective consideration; extends observational series but leaves randomized comparison open.
OBJECTIVES: There is limited consensus on the optimal strategy for surgical treatment of severe tricuspid valve pathology. At our institution, we have implemented a unique technique of using a tricuspid homograft with its supporting apparatus for partial replacement of the native tricuspid valve. We now present the long-term outcomes of these patients. METHODS: We analysed a cohort of patients who underwent partial tricuspid valve replacement using tricuspid homograft. Yearly clinical and echocardiographic follow-up was performed. Fine-Gray methods were used to estimate freedom from death and reoperation and reverse Kaplan-Meier methods were used to calculate follow-up. RESULTS: Fourteen patients were included (age range 15 days to 73 years). Indications included congenital anomalies (n = 9, 64%) and infective endocarditis (n = 5, 36%). The median follow-up was 17 years (95% confidence interval (CI) 10-21 years). Two patients (14%) died due to causes unrelated to the primary tricuspid valve surgery, and three (21%) underwent redo tricuspid valve operations. In the remaining cohort, seven (50%) were asymptomatic and two (14%) reported class II dyspnoea, while none had severe tricuspid regurgitation on echocardiogram. Estimated freedom from death was 93% at 10 years and 83% at 15 and 20 years, while estimated freedom from reoperation was 77% at 10, 15 and 20 years. CONCLUSIONS: Partial replacement of the tricuspid valve using tricuspid homograft tissue effectively restores the anatomical conformity of the native tricuspid valve and has durable long-term survival and freedom from severe tricuspid regurgitation in patients with congenital anomalies and infective endocarditis.
No takes yet. Share an insight, caveat, or question.
Raza et al. (2024) conducted a cohort in Severe tricuspid valve pathology (n=14). Partial replacement of the tricuspid valve using tricuspid homograft was evaluated on Freedom from death and reoperation. Partial tricuspid valve replacement using a tricuspid homograft yielded an estimated freedom from death of 83% and freedom from reoperation of 77% at 20 years.