Key result
Thin-film sensors accurately map guinea pig papillary muscles to reveal substantial conduction velocity dispersion.
A novel high-resolution mapping system using thin-film sensors enables precise measurement of cardiac activation patterns at a microscopic scale, revealing substantial dispersion of conduction velocities.
No immediate clinical use; leaves open translation of thin-film mapping to intact or human hearts.
To study the spread of excitation in ventricular heart preparations we have designed a fast, high-resolution recording and mapping system. Papillary muscles were dissected from the isolated guinea pig hearts. The preparation was fixed in a tissue bath and superfused with Tyrode solution. Linear and two-dimensional arrays of Ag/AgCl electrodes were made on glass with a thin-film technique. The transparent sensors with up to 24 electrodes (spaced 50, 90, or 180 microns apart) were positioned close to the surface of the preparation with a custom-designed three-dimensional micromanipulator. Extracellular signals were simultaneously recorded by a 24-channel data acquisition system with a 200 kHz per channel sample rate, with 12-bit amplitude resolution and a maximum data length of up to 3 MB. Digitized video images of the electrode array and the underlaying preparation were used to identify the locations of the recording sites. A UNIX-based computer system with a custom-designed data acquisition and database program was used to control the instruments and to manage the experimental data. This technique gave signals with excellent signal-to-noise ratios (up to 65 dB) and permitted accurate evaluation of the time and the site of the local activation with high resolution (to within 5 microseconds, 50 microns). We describe the spread of excitation within the area of a few cells and found a substantial dispersion of conduction velocities. Beat-to-beat comparison of activation patterns showed relatively small variations in the spread of excitation (a few microseconds).
No takes yet. Share an insight, caveat, or question.
Hofer et al. (1994) studied isolated guinea pig hearts. thin-film sensors recording and mapping system was evaluated on spread of excitation and local activation. A high-resolution recording system using thin-film sensors permitted accurate evaluation of local activation in guinea pig papillary muscles, revealing substantial dispersion of conduction velocities.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: