Key result
Intravenous 2% dodecafluoropentane emulsion increases LV cavity opacification by ~51% vs sonicated human albumin.
Why the study?
Does intravenous 2% dodecafluoropentane emulsion improve left ventricular cavity opacification compared to sonicated human albumin in adult patients with suboptimal echocardiograms?
RCT (n=254)
Single-blind
Yes
Does intravenous 2% dodecafluoropentane emulsion improve left ventricular cavity opacification compared to sonicated human albumin in adult patients with suboptimal echocardiograms?
Absolute Event Rate: 83% vs 55%
p-value: p=<0.0001
Intravenous 2% dodecafluoropentane emulsion is superior to sonicated human albumin for left ventricular cavity opacification and endocardial border definition in patients with suboptimal echocardiograms, with a similar safety profile.
No takes yet. Share an insight, caveat, or question.
May improve LV visualization in suboptimal echocardiograms; extends contrast options pending outcome trials.
Grayburn et al. (1998) conducted an RCT in Suboptimal echocardiograms (n=254). 2% dodecafluoropentane (DDFP) emulsion (EchoGen) vs. Sonicated 5% human albumin (Albunex) was evaluated on Full or intermediate LV cavity opacification (investigators) (p=<0.0001). Intravenous 2% dodecafluoropentane emulsion was superior to sonicated human albumin for full or intermediate LV cavity opacification (83% vs. 55% for investigators, p<0.0001).