Key result
Dobutamine stress echocardiography yields ~3x higher specificity vs exercise thallium-201 for CAD, with similar sensitivity.
Why the study?
Does dobutamine stress echocardiography improve diagnostic specificity for CAD compared to exercise thallium-201 myocardial CT in patients with permanent RV pacemakers?
Cross-Sectional (n=29)
Does dobutamine stress echocardiography improve diagnostic specificity for CAD compared to exercise thallium-201 myocardial CT in patients with permanent RV pacemakers?
Absolute Event Rate: 92% vs 31%
p-value: p=<0.01
Dobutamine stress echocardiography significantly reduces false-positive results compared to exercise thallium-201 myocardial CT in evaluating coronary artery disease in patients with permanent RV pacemakers.
Dobutamine stress echocardiography may reduce false positives for CAD in RV pacemaker patients; leaves open need for prospective validation.
This study evaluated the use of dobutamine stress echocardiography and exercise thallium-201 myocardial computed tomography (CT) in the diagnosis of coronary artery disease (CAD) in patients with permanent transvenous pacemaker with the electrode implanted in the right ventricle (RV). Twenty-nine consecutive patients with pacemaker underwent dobutamine stress echocardiography, exercise thallium-201 myocardial CT, and coronary arteriography over a period of 8 +/- 1 days. None of these patients had suffered a myocardial infarction (MI). The cardiac rhythm of every patient was electrically paced during echocardiography and tomography. Sixteen (55%) patients showed CAD on angiography (stenosis > or = 50% of the luminal diameter of a major epicardial vessel). The detection sensitivity for CAD was 94% for the tomography and 88% for the echocardiography (P = NS). The difference between the sensitivities of the two techniques in detecting CAD based on the affected coronary artery was not statistically significant. Of the 13 patients without CAD, tomography showed a positive result in nine cases, i.e., a specificity of 31%, whereas echocardiography showed a positive result in only one case, i.e., a specificity of 92% (P < 0. 01). Exercise thallium-201 myocardial computed tomography produces an increased rate of false-positive results in patients with permanent transvenous cardiac pacemaker (PCP) implanted in the right ventricle (RV). Dobutamine stress echocardiography can thus be used to reduce considerably the level of false-positive results in these patients and still retain a detection sensitivity for CAD equal to that of myocardial tomography.
No takes yet. Share an insight, caveat, or question.
Ciaroni et al. (2000) conducted a cross-sectional in Coronary artery disease in patients with permanent cardiac pacemaker (n=29). Dobutamine stress echocardiography vs. Exercise thallium-201 myocardial computed tomography was evaluated on Specificity for detecting coronary artery disease (p=<0.01). Dobutamine stress echocardiography yielded significantly higher specificity (92% vs 31%, P<0.01) and similar sensitivity (88% vs 94%, P=NS) compared to exercise thallium-201 tomography for detecting CAD.