Key result
Exercise Doppler echocardiography demonstrates high reproducibility for assessing the right heart and pulmonary circulation.
Why the study?
Quality control of resting and exercise echocardiography variables was needed among experienced echocardiography laboratories participating in the RIGHT Heart International NETwork.
Does exercise Doppler echocardiography provide reproducible measurements of the right heart and pulmonary circulation across expert centers?
Observational
Yes
Does exercise Doppler echocardiography provide reproducible measurements of the right heart and pulmonary circulation across expert centers?
Effect estimate: ICC > 0.80
Exercise Doppler echocardiography is a highly reproducible tool for assessing the right heart and pulmonary circulation when performed in expert centers.
Enables reliable multicenter research on exercise hemodynamics; leaves open validation for routine clinical use.
Purpose: This study was a quality-control study of resting and exercise echocardiography (EDE) variables measured by 19 echocardiography laboratories with proven experience participating in the RIGHT Heart International NETwork. Methods: All participating investigators reported the requested variables from ten randomly selected exercise stress tests. Intraclass correlation coefficients (ICC) were calculated to evaluate the inter-observer agreement with the core laboratory. Inter-observer variability of resting and peak exercise tricuspid regurgitation velocity (TRV), right ventricular outflow tract acceleration time (RVOT Act), tricuspid annular plane systolic excursion (TAPSE), tissue Doppler tricuspid lateral annular systolic velocity (S’), right ventricular fractional area change (RV FAC), left ventricular outflow tract velocity time integral (LVOT VTI), mitral inflow pulsed wave Doppler velocity (E), diastolic mitral annular velocity by TDI (e’) and left ventricular ejection fraction (LVEF) was measured. Results: The accuracy of 19 investigators for all variables ranged from 99.7% to 100%. ICC was > 0.80 for all observers. Inter-observer variability for resting and exercise variables was for TRV = 3.8 to 2.4%, E = 5.7 to 8.3%, e’ = 6 to 6.5%, RVOT Act = 9.7 to 12, LVOT VTI = 7.4 to 9.6%, S’= 2.9 to 2.9% and TAPSE = 5.3 to 8%. Moderate inter-observer variability was found for resting and peak exercise RV FAC (15 to 16%). LVEF revealed lower resting and peak exercise variability of 7.6 and 9%. Conclusions: When performed in expert centers EDE is a reproducible tool for the assessment of the right heart and the pulmonary circulation
No takes yet. Share an insight, caveat, or question.
Ferrara et al. (2020) conducted an observational in Right heart and pulmonary circulation assessment. Resting and exercise Doppler echocardiography (EDE) vs. Core laboratory was evaluated on Inter-observer agreement (Intraclass correlation coefficients) and variability (ICC > 0.80). Exercise Doppler echocardiography demonstrated high reproducibility for assessing the right heart and pulmonary circulation, with intraclass correlation coefficients >0.80 across 19 expert centers.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: