Key result
Phased array ICE accurately quantifies low-temperature RF ablation lesion size in a canine model.
Why the study?
Does phased array intracardiac echocardiography accurately quantify low temperature radiofrequency ablation lesion size compared to pathology in a canine model?
Does phased array intracardiac echocardiography accurately quantify low temperature radiofrequency ablation lesion size compared to pathology in a canine model?
Phased array intracardiac echocardiography is feasible for real-time evaluation of low temperature radiofrequency ablation lesion size, though it slightly overestimates the necrotic core compared to pathology.
Provides preclinical support for ICE lesion monitoring in ablation; leaves open human validation and clinical adoption.
OBJECTIVE: To evaluate the feasibility of quantifying low temperature radiofrequency catheter ablation (RFCA) lesions using a phased array intracardiac echocardiography (ICE) catheter--with better tissue penetration and in a deflectable device-in the canine model. INTERVENTION: Low temperature radiofrequency (RF) energy (50-60 degrees C at up to 40 W) was delivered to the left ventricle in 11 beagles for 60 seconds, using an 8 French catheter with a deflectable tip and a 4 mm distal electrode. MAIN OUTCOME MEASURES: Comparison of the width and depth of RFCA lesions measured by ICE with pathological findings. RESULTS: 33 RF energies were delivered in 11 dogs. 31 lesions (94%) were confirmed at necropsy. 27 of 31 ablation lesions (87%) were detected by ICE. The mean (SD) width and depth of the ICE detected lesions were 10.4 (2.6) mm and 5.7 (1.9) mm, respectively. Pathological findings showed that RFCA lesions consisted of inner and outer layers. Macroscopically, the mean (SD) width and depth of the inner layers were 7.6 (2.3) mm and 3.6 (1.2) mm and those for the whole layers were 10.0 (2.8) mm and 5.3 (1.5) mm, respectively. Microscopically, the inner and outer layers corresponded to necrotic and oedematous areas, respectively. The ICE detected lesion size had better correlation with the pathological measurements of the whole layers in width (r = 0.911) and in depth (r = 0.756). CONCLUSION: The real time evaluation of RFCA lesion size using the phased array ICE is feasible, even with a low temperature RF application. However, ICE slightly overestimates RFCA lesion size compared with pathological necrotic lesion size.
No takes yet. Share an insight, caveat, or question.
Atsushi Doi (2003) studied this question. Phased array intracardiac echocardiography (ICE) vs. Pathological findings was evaluated on Comparison of the width and depth of RFCA lesions measured by ICE with pathological findings (r = 0.911 (width), r = 0.756 (depth)). Phased array intracardiac echocardiography accurately quantified low temperature radiofrequency ablation lesion size in a canine model, correlating well with pathological whole layer width (r=0.911) and depth (r=0.756).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: