Key result
Subclavian 16F laser sheath and femoral Needle's Eye approach successfully extract dual-coil ICD and atrioverter leads.
Highlights a tailored approach using different extraction tools and access sites for complex lead removal in a single patient.
Answers are grounded in this paper and cite their sources.
May support tailored multi-tool extraction in complex cases; leaves open generalizability and safety in larger cohorts.
A dual-coil ICD lead and an atrioverter coiled lead implanted in the right ventricle and coronary sinus, respectively, were successfully removed with different techniques. For the ICD lead, we used a 16F laser sheath from the subclavian and for the atrioverter lead a Needle's Eye from the femoral approach.
No takes yet. Share an insight, caveat, or question.
Gelder et al. (2010) studied this question. Extraction of a dual-coil ICD lead and a coronary sinus atrioverter lead was successfully achieved using a subclavian 16F laser sheath and a femoral Needle's Eye approach.
Synapse has enriched 10 related papers. Consider them for comparative context: