This is the authors' abstract. We don't add key points for this paper.
Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm(-1), yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm(-1) and 1093 cm(-1). This indicates that spectroscopy at these two specific wavenumbers alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: