Answers are grounded in this paper and cite their sources.
Objective. Accurate proton dosimetry requires internally consistent stopping-power data for detector-to-water dose conversion and Monte Carlo radiation transport simulations. This study quantifies how water-to-silicon stopping-power ratios, converted dose-to-water distributions, and Bragg-peak metrics vary with the stopping-power dataset for a 67.5 MeV pristine proton beam in water. Approach. PHITS simulations were performed using dataset-specific stopping powers from SRIM-2013, PSTAR/NIST, ATIMA, and TDDFT-Penn for proton energies up to 10 MeV, combined with a common SBETHE-based high-energy extension above 10 MeV. Normalized percentage depth-ionization data from the PTW silicon diode in the published benchmark of Faddegon et al. (2015) were converted into relative percentage depth- dose distributions in water using depth-dependent water-to-silicon stopping-power ratios. Direct dose-to-water simulations were performed to evaluate Bragg-peak and distal-range metrics. Main results. The water-to-silicon stopping-power ratio exhibited a pronounced depth dependence, with relative entrance-to-distal variations ranging from 17.40% to 22.10% across the datasets. All converted relative PDD curves reached their maximum at 36.86 mm, with no dataset-dependent shift. This position agrees with the experimental Bragg-peak depth of (36.81 ± 0.15) mm, defined as the midpoint between adjacent PDI maxima at 36.76 and 36.86 mm. The converted curves were approximately 3% below the reference curve throughout the entrance and plateau regions, while dataset-dependent deviations of up to 2.1% were observed near the Bragg peak. Direct PHITS calculations predicted Bragg-peak depths ranging from 36.575 to 36.675 mm; only the TDDFT-Penn result lay within the quoted experimental uncertainty. Significance. For this benchmark, the stopping-power treatment affects the normalization of the converted dose throughout the entrance, plateau, and distal regions more strongly than it affects the Bragg-peak position. Harmonizing stopping-power data between detector-to-water conversion and Monte Carlo transport, or explicitly including dataset dependence in the uncertainty budget, is important for proton-beam calibration, commissioning, quality assurance, and Monte Carlo validation.
No takes yet. Share an insight, caveat, or question.
Matias et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: