Answers are grounded in this paper and cite their sources.
Background and Aims. Differences between LEM1- and mMKM-based clinical dose systems complicate the translation of RBE-weighted dose in carbon ion radiotherapy, while uncertainties associated with RBE model parameterisation complicate the interpretation of predicted RBE. This work establishes two complementary dose-averaged LET (LET d )-based frameworks to (i) analytically convert RBE between the two systems and (ii) characterise systematic fitting uncertainties and their propagation into RBE. Methods. Monte Carlo simulations of clinical carbon‑ion pencil beams and SOBPs in water were performed using GATE 10/Geant4.11.3.2 within the IDEAL 2 platform. LET d , mixed-beam radiosensitivity α mix , and RBE distributions were computed for both clinical dose systems. Ion-specific α Z,E tables were obtained from saturation-corrected dose-averaged specific energy z * 1D and intrinsic coefficient α z tables computed by internally developed PRUDENT code. Relationship between ε α and ε RBE , which quantify the mMKM-LEM1 relative differences in α mix and RBE, respectively, was derived and approximated using linear functions. The ε α (LET d ) relationship was fitted from simulated α mix and LET d . The full analytical framework was validated in SOBP target regions against computed ε RBE . Systematic fitting uncertainty in mMKM, denoted as η RBE , was characterized by comparing simulated α mix with published in vitro α fit reference at equal LET d , and evaluated for physical dose D=0-8 Gy. Main results. The ε α ranged from -20% at LET d =33 keV/μm to 18% at LET d =95 keV/μm in the target region of SOBP, well described by a logarithmic-logistic form. The linear approximation ε RBE =k·ε α +b predicted the ε RBE within ±1% when ε α was known, and within 3-4% when fitted ε α (LET d ) was used. Large η α was observed, reaching 275% at LET d =22.5 keV/μm and decreasing to -22% at LET d =137 keV/μm. The resulting η RBE exceeded 100% in the low-D-low-LET d region. Significance. This work provides the first closed-form, LET d -based frameworks for RBE conversion in LEM1- and mMKM-based clinical systems and LET d -related uncertainty quantification in the latter. The results reveal the mechanistic link between LET d and ε α and between LET d and η α arising from particle LET spectra, and support LET d -informed plan evaluation.
No takes yet. Share an insight, caveat, or question.
Jia et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: