Answers are grounded in this paper and cite their sources.
The relationship between radiation track structure and biological effectiveness remains a challenge in radiobiology, particularly for charged-particle therapy. In this work, we present a framework linking nanodosimetric descriptors of ionisation clustering to cellular response. Monte Carlo track-structure simulations using Geant4-DNA were performed for protons, alpha particles and carbon ions over a range of linear energy transfer (LET) values up to 200 keV/µm. The resulting ionisation cluster-size distributions were completed by estimating the zero-ionisation contribution using a dual-GPD model. From the reconstructed distributions, nanodosimetric quantities such as the mean cluster size M1 and the weighted cumulative probability R2 were derived, which account for the combined effect of multiple ionisations on the production of lethal DNA damage. A direct link between nanodosimetry and cell survival data was established through the effective inactivation cross section at 5% survival, derived from a Bayesian-bootstrap estimates of linear–quadratic model parameters for human cell lines. Both analysed parameters M1 and R2 exhibit sensitivity not only to LET but also to particle type. These findings demonstrate that LET alone is insufficient to fully characterise radiation quality, highlighting the importance of explicitly accounting for the spatial distribution of ionisation events. For normal cells, σ5% shows a linear dependence on R2, with a slope interpreted as an effective cross-sectional area of radiosensitive nuclear regions, rather than the geometrical area of the entire nucleus. For tumour cells, variations in radiosensitivity are captured by a single parameter p of R2 model describing the probability of lethal damage accumulation. The cell lines with lower fitted p values (relatively radioresistant) exhibited steeper fitted RBE-LET relationships than those with higher fitted p values (relatively radiosensitive). However, the differences were not statistically significant and should be interpreted as an exploratory finding. The proposed framework provides a physically motivated link between ionisation track structure and biological response. Its potential application to ion-beam treatment planning requires further biological and treatment-plan-level validation.
No takes yet. Share an insight, caveat, or question.
Filipek et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: