Key result
Direct ion channel assays reduce artifact and improve hit confirmation over indirect measures despite lower throughput.
Why the study?
Ion channels are important drug targets but challenging to screen due to lack of robust high-throughput assays, especially for state-dependent interactions.
Direct functional assays for ion channels offer higher quality data with fewer artifacts, and an iterative screening approach can overcome their lower throughput limitations.
Answers are grounded in this paper and cite their sources.
Direct assays may enhance screening quality for ion channel modulators; leaves open scalable integration into cardiovascular drug pipelines.
IMPORTANCE OF THE FIELD: Ion channels are important targets for many disease areas but are challenging to screen due to lack of technologies enabling robust high-throughput assays, particularly for state-dependent interactions. AREAS COVERED IN THIS REVIEW: Current assay technologies used to measure ion channel function are reviewed and assessed for use in high-throughput screening (HTS). An iterative approach to screening is evaluated as an alternative to full collection screening in order to take advantage of low-throughput, high cost assays that yield high quality data. WHAT THE READER WILL GAIN: The reader will gain an understanding of the advantages and disadvantages of various assay techniques used to screen ion channels and their suitability for use in HTS. TAKE HOME MESSAGE: Assays that directly measure ion channel function are prone to less artifact and higher hit confirmation in screening than those using an indirect measure but they are usually lower throughput. However, an iterative approach to screening can make the relatively lower throughput techniques amenable for use in interrogating large collections of compounds.
No takes yet. Share an insight, caveat, or question.
Trivedi et al. (2010) conducted a review in Ion channel targets. Functional assays for high-throughput screening was evaluated. Assays that directly measure ion channel function are prone to less artifact and higher hit confirmation in screening than indirect measures, though they are usually lower throughput.