Key result
Anterior mitral leaflet motion on echo allows noninvasive estimation of transmitral flow velocity.
Why the study?
Does anterior mitral leaflet motion on echocardiography accurately reflect transmitral blood flow in patients undergoing cardiac catheterization?
Observational (n=11)
Does anterior mitral leaflet motion on echocardiography accurately reflect transmitral blood flow in patients undergoing cardiac catheterization?
Anterior mitral leaflet motion on echocardiography can noninvasively approximate the relative velocity of transmitral flow and the percent of stroke volume entering the left ventricle.
Answers are grounded in this paper and cite their sources.
May support noninvasive transmitral flow estimation; leaves open prospective validation before clinical adoption.
Transmitral blood flow was measured in man by numerical differentiation of left ventricular volume as a function of time in 11 patients undergoing cardiac catheterization. Using this technique, transmitral blood flow may be studied in a variety of pathologic states without the need for surgically introduced flowmeters. Just before left ventriculography, echocardiography of the mitral valve was performed. The pattern of transmitral blood flow was strikingly similar to the diastolic movement of the anterior mitral leaflet. At any equivalent diastolic filling time, the percent of the integrated area beneath the curve inscribed by the diastolic anterior mirtal leaflet echoes closely approximated the percent of stroke volume which had entered the left ventricle. This observation supports the hypothesis that mitral leaflet motion accurately reflects transmitral flow. Consequently, at a given time during diastole, the relative velocity of transmitral flow and the percent of the stroke volume which has entered the left ventricle may be approximated noninvasively from the anterior mitral leaflet echogram.
No takes yet. Share an insight, caveat, or question.
Laiken et al. (1979) conducted an observational in Patients undergoing cardiac catheterization (n=11). Anterior mitral leaflet echogram vs. Invasive measurement of transmitral blood flow via left ventriculography was evaluated on Correlation between anterior mitral leaflet motion and transmitral blood flow. Anterior mitral leaflet motion on echocardiography closely approximated the percent of stroke volume entering the left ventricle, allowing noninvasive estimation of transmitral flow velocity.
Synapse has enriched 10 related papers. Consider them for comparative context: