Key result
Hypertensive rats show ~62% lower nitric oxide release rates than normotensive controls.
Endothelial dysfunction in hypertension and hypercholesterolemia is characterized by a significant decrease in the rate and peak concentration of nitric oxide release, which can be measured using nanosensors.
Answers are grounded in this paper and cite their sources.
Suggests endothelial dysfunction via reduced NO release in hypertensive models; leaves open translation to human diagnostics or therapy.
The endothelium plays a critical role in maintaining vascular tone by releasing nitric oxide (NO). Endothelium derived NO diffuses to smooth muscles, triggering their relaxation. The dynamic of NO production is a determining factor in signal transduction. The present studies were designed to elucidate dynamics of NO release from normal and dysfunctional endothelium. The nanosensors (diameter 100-300 nm) exhibiting a response time better than 100 micros and detection limit of 1.0 x 10(-9) mol L(-1) were used for in vitro monitoring of NO release from single endothelial cells from the iliac artery of normotensive (WKY) rats, hypertensive (SHR) rats, and normal and cholesterolemic rabbits. Also, the dynamics and distribution of NO in left ventricular wall of rabbit heart were measured. The rate of NO release was much higher (1200 +/- 50 nmol L(-1) s(-1)) for WKY than for SHR (460 +/- 10 nmol L(-1) s(-1)). Also, the peak NO concentration was about three times higher for WKY than SHR. Similar decrease in the dynamics of NO release was observed for cholesterolemic rabbits. The dynamics of NO release changed dramatically along the wall of rabbit aorta, being highest (0.86 +/- 0.12 micromol L(-1)) for the ascending aorta, and lowest for the iliac aorta (0.48 +/- 0.15 micromol L(-1)). The distribution of NO in the left ventricular wall of rabbit heart was not uniform and varied from 1.23 +/- 0.20 micromol L(-1) (center) to 0.90 +/- 0.15 micromol L(-1) (apex). Both, the maximal concentration and the dynamics of NO release can be useful diagnostic tools in estimating the level of endothelial dysfunction and cardiovascular system efficiency.
No takes yet. Share an insight, caveat, or question.
Balbatun et al. (2003) studied Endothelial dysfunction. Hypertension (SHR rats) vs. Normotension (WKY rats) was evaluated on Rate of NO release. The rate of nitric oxide release was substantially lower in hypertensive rats (460 nmol/L/s) compared to normotensive rats (1200 nmol/L/s).
Synapse has enriched 10 related papers. Consider them for comparative context: