Key result
AVR with the St. Jude Trifecta bioprosthesis demonstrates excellent haemodynamics and 2.5% 30-day mortality.
Observational (n=200)
No
The Trifecta aortic bioprosthesis demonstrates excellent early hemodynamic performance with low gradients and minimal aortic insufficiency.
Answers are grounded in this paper and cite their sources.
Supports early Trifecta valve use based on low gradients and mortality; extends observational data but leaves durability and comparative efficacy open.
OBJECTIVES: The St. Jude Medical Trifecta aortic bioprosthesis (St. Jude Medical, Inc., St. Paul, MN, USA) is a new stented pericardial tissue heart valve. The aim of the study was to evaluate the clinical and haemodynamic performance of the Trifecta bioprosthesis in the early postoperative period. METHODS: From July 2010 to September 2012, a total of 200 consecutive patients underwent aortic valve replacement with the Trifecta valve in our institution. All intraoperative and postoperative data were prospectively collected. Mean EuroSCORE II was 3.98%. Echocardiography was performed at discharge in all patients. RESULTS: The mean age was 71.2 ± 7.7 (range 39-89 years). Extubation in the operating theatre was successfully performed in 96% of patients. Mean hospital stay was 8.5 days. The prosthesis sizes were 19 mm (n = 33), 21 mm (n = 81), 23 mm (n = 59), 25 mm (n = 23) and 27 mm (n = 4). Mean systolic pressure gradients ranged from 9.4 mmHg (size 19 valve) to 4.8 mmHg (size 27 valve). Mean effective orifice area (EOA) ranged from 1.61 cm(2) (size 19 valve) to 2.5 cm(2) (size 27 valve). Severe mismatch (<0.65 cm(2)/m(2)) did not occur in any patient. Of note, 99.5% of patients had mild or no aortic insufficiency at discharge. The early (30-day) mortality was 2.5% (n = 5). CONCLUSIONS: The Trifecta valve offers good clinical results and excellent haemodynamic performance. Special care must be taken to avoid oversizing, which can lead to difficulty in implantation and can produce gradient increases due to an excess of prosthetic leaflet tissue.
No takes yet. Share an insight, caveat, or question.
Permanyer et al. (2013) conducted an observational in Aortic valve replacement (n=200). St. Jude Medical Trifecta aortic bioprosthesis was evaluated on Clinical and haemodynamic performance (including 30-day mortality). Aortic valve replacement with the St. Jude Medical Trifecta bioprosthesis demonstrated excellent haemodynamic performance and an early 30-day mortality of 2.5%.
Synapse has enriched 10 related papers. Consider them for comparative context: