Key result
Lumenless trans-septal LV endocardial pacing enables safe and effective CRT in difficult CS anatomy.
Why the study?
To achieve cardiac resynchronization in a patient with severe ischemic cardiomyopathy and a non-negotiable coronary sinus ostium.
Is trans-septal left ventricular endocardial pacing feasible and safe in a patient with severe ischemic cardiomyopathy and non-negotiable coronary sinus ostium?
Case Report (n=1)
Is trans-septal left ventricular endocardial pacing feasible and safe in a patient with severe ischemic cardiomyopathy and non-negotiable coronary sinus ostium?
Trans-septal left ventricular endocardial pacing offers a feasible alternative for cardiac resynchronization in patients with difficult coronary sinus anatomy.
May enable CRT when coronary sinus access fails; leaves open durability, safety, and generalizability.
OBJECTIVE: To achieve cardiac resynchronization in a patient with severe ischemic cardiomyopathy with non-negotiable coronary sinus ostium. KEY STEPS: A 260-cm coated 0.035-inch wire was advanced into the descending thoracic aorta through the left atrium and left ventricle after trans-septal puncture from the femoral venous route, which was then snared out through the right femoral artery. The other end of the wire was snared out from the left subclavian vein. A sheath with dilator was advanced over this wire to the left ventricular free wall. A thin, lumenless bipolar pacing lead was advanced through the sheath, implanted into the left ventricular lateral wall, and connected to the pulse generator. POTENTIAL PITFALLS: The risk of thromboembolism and worsening mitral regurgitation are 2 major concerns; they may be avoided by using a thinner lead and strict anticoagulation. TAKE-HOME MESSAGE: Trans-septal left ventricular endocardial pacing using a thinner, lumenless lead is feasible, safe, and effective.
No takes yet. Share an insight, caveat, or question.
Das et al. (2025) conducted a case report in Severe ischemic cardiomyopathy with non-negotiable coronary sinus ostium (n=1). Trans-septal left ventricular endocardial pacing using a thinner, lumenless lead was evaluated on Feasibility, safety, and effectiveness. Trans-septal left ventricular endocardial pacing using a thinner, lumenless lead is feasible, safe, and effective for achieving cardiac resynchronization in difficult coronary sinus anatomy.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: