Key result
Ameroid constrictors induce severe global LV dysfunction in dogs, decreasing LV size change by ~50%.
Why the study?
The mechanism(s) of left ventricular dysfunction in chronic coronary artery disease remain controversial due to the lack of an appropriate animal model.
This canine model of multivessel stenosis closely mimics human chronic ischemic LV dysfunction, demonstrating that regional dysfunction can occur with or without a decrease in myocardial blood flow.
Answers are grounded in this paper and cite their sources.
Supports canine multivessel stenosis model for ischemic LV dysfunction research; leaves open translation to human disease mechanisms or therapies.
The controversy regarding the mechanism(s) of left ventricular (LV) dysfunction in chronic coronary artery disease is, in part, related to the lack of an appropriate animal model for this condition. We have developed such a model by placing Ameroid constrictors on proximal portions of coronary arteries in dogs who were euthanized (mean of 6 wk) after the development of severe global LV dysfunction noted on two-dimensional echocardiography. The LV end-systolic size nearly doubled (P < 0.001) over the observation period, and the percent change in LV size from end diastole to end systole decreased by >50% (P < 0.001). Regional dysfunction was noted in 23 of 24 myocardial beds analyzed within regions showing no gross evidence of infarction. In 10 of these beds, severe dysfunction was noted without a decrease in radiolabeled microsphere-derived myocardial blood flow (MBF). In 13 myocardial beds, decrease in function was associated with a decrease in MBF (P < 0.001), with close coupling noted between percent wall thickening and MBF. In the beds that exhibited an ultimate decrease in MBF, the decrease in function preceded the decrease in MBF. In conclusion, we describe chronic LV dysfunction in a canine model of multivessel stenosis that closely mimics chronic ischemic LV dysfunction in humans. Whereas regional function is severely reduced in this model, MBF is varied in different segments and at different times during the observation period. These results provide new insights regarding flow-function relations in chronic ischemic LV dysfunction.
No takes yet. Share an insight, caveat, or question.
Firoozan et al. (1999) studied Chronic ischemic cardiomyopathy. Placement of Ameroid constrictors on proximal coronary arteries vs. Baseline was evaluated on LV end-systolic size and percent change in LV size from end diastole to end systole (p=<0.001). Placement of Ameroid constrictors in dogs induced severe global LV dysfunction, with LV end-systolic size nearly doubling and percent change in LV size decreasing by >50%.
Synapse has enriched 10 related papers. Consider them for comparative context: