Why the study?
It was hypothesized that real-time simultaneous amplitude frequency electrogram transform during sinus rhythm can identify and characterize drivers of atrial fibrillation in nonparoxysmal atrial fibrillation.
Does SAFE-T mapping during sinus rhythm identify AF drivers in patients with nonparoxysmal atrial fibrillation?
Observational (n=21)
Does SAFE-T mapping during sinus rhythm identify AF drivers in patients with nonparoxysmal atrial fibrillation?
SAFE-T mapping during sinus rhythm is feasible for identifying and characterizing sites of AF drivers in patients with nonparoxysmal atrial fibrillation.
Answers are grounded in this paper and cite their sources.
SAFE-T mapping may identify AF drivers; hypothesis-generating for nonparoxysmal AF ablation pending randomized trials.
INSTRUCTION: We hypothesized that real-time simultaneous amplitude frequency electrogram transform (SAFE-T) during sinus rhythm (SR) is able to identify and characterize the drivers of atrial fibrillation (AF) in nonparoxysmal (NP) AF. METHODS: Twenty-one NPAF patients (85.71% males, mean age 52 years old) underwent substrate mapping during SR (SAFE-T and voltage) and during AF (complex fractionated atrial electrograms [CFAE] and similarity index [SI]). After pulmonary veins isolation, extensive substrate ablation was performed with the endpoint of procedural termination or elimination of all SI sites (>63% similarities). Sites with procedural termination and non-termination sites were tagged for postablation SR analysis using SAFE-T. RESULTS: In 74 CFAE sites identified (average of 3 ± 2 sites per person), 28 (37.84%) were identified as termination sites demonstrating a high SI compared with the non-termination sites (80.11 ± 9.57% vs. 45.96 ± 13.38%, p < .001) during AF. During SR, these termination sites have high SAFE-T values and harbor a highly resonant, localized, repetitive high frequency components superimposed in the low frequency components compared with non-termination sites (5.70 ± 3.04 vs. 1.49 ± 1.66 Hz·mV, p < .001). In the multivariate analysis, the termination sites have higher SAFE-T and SI value (p < .001). CONCLUSION: AF procedural termination sites harbored signal characteristics of repetitive, high frequency component of individualized electrogram during SR, which can be masked by the low frequency fractionated electrogram and are difficult to see from the bipolar electrogram. Thus, SAFE-T mapping is feasible in identifying and characterizing sites of AF drivers.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2023) conducted an observational in Nonparoxysmal atrial fibrillation (n=21). AF procedural termination sites vs. Non-termination sites was evaluated on SAFE-T values during sinus rhythm (p=<.001).
Synapse has enriched 10 related papers. Consider them for comparative context: