Key result
Indicator-dilution methods require a ventricular mixing chamber to accurately determine true pulmonary blood volume.
Why the study?
The validity of pulmonary blood volume determination methods with or without a ventricular mixing chamber was uncertain.
Does the presence of a ventricular mixing chamber improve the validity of true pulmonary blood volume determination by indicator-dilution methods?
Does the presence of a ventricular mixing chamber improve the validity of true pulmonary blood volume determination by indicator-dilution methods?
A ventricular mixing chamber is essential for valid determination of true pulmonary blood volume using indicator-dilution methods.
Answers are grounded in this paper and cite their sources.
Indicator-dilution pulmonary blood volume estimates may be invalid without ventricular mixing; leaves open in vivo validation.
"True" pulmonary blood volume has been determined by three indicator-dilution methods in 96 subjects. In two methods a right or left ventricular mixing chamber is interposed between the injection and sampling sites while in the third such a mixing chamber is absent. The results strongly suggest that a ventricular mixing chamber is essential for valid determination of true pulmonary blood volume.
No takes yet. Share an insight, caveat, or question.
Samet et al. (1966) studied this question. Indicator-dilution methods require a right or left ventricular mixing chamber between injection and sampling sites for the valid determination of true pulmonary blood volume.