Key result
Simulations reveal aortic valve interstitial cells exhibit ~5% creep during diastole but act elastically during closure.
Absolute Event Rate: 4.65% vs 7.92%
AVIC viscoelastic effects are negligible during valve closure but likely contribute to deformation time-history during diastole.
AVIC viscoelasticity may shape diastolic valve deformation in models; animal data leaves open relevance to human valve repair or durability.
There has been growing interest in the mechanobiological function of the aortic valve interstitial cell (AVIC) due to its role in valve tissue homeostasis and remodeling. In a recent study we determined the relation between diastolic loading of the aortic valve (AV) leaflet and the resulting AVIC deformation, which was found to be substantial. However, due to the rapid loading time of the AV leaflets during closure ( approximately 0.05 s), time-dependent effects may play a role in AVIC deformation during physiological function. In the present study, we explored AVIC viscoelastic behavior using the micropipette aspiration technique. We then modeled the resulting time-length data over the 100 s test period using a standard linear solid model, which included Boltzmann superposition. To quantify the degree of creep and stress relaxation during physiological time scales, simulations of micropipette aspiration were preformed with a valve loading time of 0.05 s and a full valve closure time of 0.3 s. The 0.05 s loading simulations suggest that, during valve closure, AVICs act elastically. During diastole, simulations revealed creep (4.65%) and stress relaxation (4.39%) over the 0.3 s physiological time scale. Simulations also indicated that if Boltzmann superposition was not used in parameter estimation, as in much of the micropipette literature, creep and stress relaxation predicted values were nearly doubled (7.92% and 7.35%, respectively). We conclude that while AVIC viscoelastic effects are negligible during valve closure, they likely contribute to the deformation time-history of AVIC deformation during diastole.
No takes yet. Share an insight, caveat, or question.
Merryman et al. (2009) studied Aortic valve interstitial cell mechanics. Micropipette aspiration and standard linear solid model simulations vs. Simulations without Boltzmann superposition was evaluated on Creep and stress relaxation during diastole (0.3 s time scale). Simulations of micropipette aspiration revealed that aortic valve interstitial cells exhibit creep (4.65%) and stress relaxation (4.39%) during diastole, while acting elastically during valve closure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: