Key result
M-mode cross-section ultrasound yields similar FMD values compared to conventional B-mode imaging.
Why the study?
Flow-mediated vasodilation of the brachial artery is a widely used noninvasive method for evaluating endothelial function, but the suitability of M-mode ultrasonography for this measurement compared to the conventional B-mode method was unclear.
Does M-mode ultrasonography on cross-section images provide comparable FMD measurements to conventional B-mode ultrasonography in evaluating endothelial function?
Cross-Sectional (n=37)
Does M-mode ultrasonography on cross-section images provide comparable FMD measurements to conventional B-mode ultrasonography in evaluating endothelial function?
Absolute Event Rate: 8.98% vs 8.14%
p-value: p=0.84
M-mode ultrasonography on cross-section images is a feasible and accurate alternative to conventional B-mode for measuring brachial artery flow-mediated vasodilation without the need for electrocardiography.
Supports M-mode cross-sectional imaging as equivalent for FMD assessment; leaves open routine adoption without further validation.
PURPOSE: Endothelial dysfunction is well known as a risk marker for initiation and progression of atherosclerosis. Flow-mediated vasodilation (FMD) of the brachial artery induced by postischemic forearm hyperemia is a widely used noninvasive method for evaluating endothelial function. M-mode ultrasonography offers high spatial and temporal resolution and is therefore suitable for diameter measurement of pulsatile vessels. We intended to compare FMD values obtained by M-mode on cross-section images and by the conventional method, ie, measurement with B-mode ultrasonography on longitudinal images. METHODS: We recruited 37 subjects (19 women, mean age: 48.3 ± 15.2 years; range: 23-71 years) in whom we measured the brachial artery diameters at baseline and at maximum dilation after forearm ischemia. FMD was calculated as the percentage of postischemic dilation. RESULTS: Baseline (3.92 ± 0.72 versus 3.91 ± 0.58 mm; p = 0.97) and maximal dilated diastolic diameter (4.26 ± 0.76 versus 4.23 ± 0.61 mm; p = 0.84), FMD (8.98 ± 3.84 versus 8.14 ± 1.99%; p = 0.84), and time to maximum dilation (48.7 ± 9.0 versus 49.3 ± 6.4 seconds, p = 0.64) were not different between the two methods. CONCLUSIONS: M-mode brachial artery diastolic and systolic diameter measurement is feasible, suitable, and accurate for the assessment of FMD without the need for electrocardiography.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2012) conducted a cross-sectional in Endothelial dysfunction evaluation (n=37). M-mode ultrasonography on cross-section images vs. B-mode ultrasonography on longitudinal images was evaluated on Flow-mediated vasodilation (FMD) (p=0.84). M-mode ultrasonography on cross-section images yielded similar flow-mediated vasodilation values compared to conventional B-mode imaging (8.98% vs 8.14%; p=0.84).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: