Key result
LV infusion with RV sampling yields higher calculated lactate turnover versus femoral venous infusion.
Why the study?
Previous studies showed differences in venous versus arterial lactate specific activity during tracer lactate infusion, necessitating comparison of infusion sites for accurate lactate turnover measurement.
The site of tracer infusion and blood sampling significantly affects the calculated lactate turnover rate, with LV infusion and RV sampling overestimating circulating lactate turnover.
Answers are grounded in this paper and cite their sources.
Infusion and sampling site selection may overestimate lactate turnover; leaves open standardized protocols for metabolic research.
Previous studies have shown that venous lactate specific activity during arterial tracer lactate infusion differs from arterial lactate specific activity during systemic venous tracer lactate infusion. We performed paired experiments on chronically catheterized rabbits to compare left ventricular (LV) infusion with femoral venous (FV) infusion of L-[U-14C]lactate. Blood was sampled from both the femoral artery (FA) and right ventricle (RV) during both modes of infusion. The mean lactate specific activity measured for each combination (infusion site, sampling site) was (FV,FA) 4,380 +/- 452, (FV,RV) 4,370 +/- 471, (LV,FA) 4,364 +/- 239, and (LV,RV) 3,325 +/- 240 (SE) dpm/mumol. Lactate turnover calculated from the specific activity in the (LV,RV) mode was significantly higher than from the other three modes (P less than 0.001). Models of lactate turnover are discussed demonstrating that the (FV,FA) and analogous modes of infusion sampling measure the turnover rate of lactate molecules that cycle through the circulation. This estimate of turnover is less than the turnover rate by the whole organism to the extent that some produced lactate is metabolized locally without entering the general circulation. The turnover calculated by the (LV,RV) mode overestimates the turnover of circulating lactate and relates to whole body lactate turnover in a complex manner.
No takes yet. Share an insight, caveat, or question.
Binder et al. (1991) studied this question. Left ventricular (LV) infusion of L-[U-14C]lactate vs. Femoral venous (FV) infusion of L-[U-14C]lactate was evaluated on Lactate specific activity (dpm/mumol) and calculated lactate turnover (p=<0.001). Lactate turnover calculated from left ventricular infusion and right ventricular sampling was higher than from femoral venous infusion.
Synapse has enriched 10 related papers. Consider them for comparative context: