Key result
World Heart Federation AMVL measurement demonstrates poor inter-rater reproducibility that zoom-optimized protocols fail to improve.
Why the study?
Studies assessing the reliability of World Heart Federation anterior mitral valve leaflet measurements are limited by bias in test-retest analyses.
Is the World Heart Federation (WHF) anterior mitral valve leaflet (AMVL) thickness measurement reliable in patients with previous acute rheumatic fever?
Observational (n=16)
Image randomization
Is the World Heart Federation (WHF) anterior mitral valve leaflet (AMVL) thickness measurement reliable in patients with previous acute rheumatic fever?
Effect estimate: ICC 0.29 and 0.46 (highest agreement)
The current WHF AMVL measurement demonstrates poor reproducibility and is only moderately repeatable, suggesting it is not a reliable assessment for rheumatic heart disease.
Poor AMVL measurement reproducibility cautions against sole reliance in RHD screening; leaves open need for refined, prospectively validated criteria.
BACKGROUND: Studies determining the reliability of the World Heart Federation (WHF) anterior mitral valve leaflet (AMVL) measurement are limited by the introduction of bias in their test-retest analyses. This study sought to determine the reliability of the current AMVL measurement while controlling for systematic bias. METHODS: Retrospective analysis of echocardiographic data from 16 patients with previous acute rheumatic fever was performed. Included in this study was an optimized cine loop of the mitral valve (MV) [reader-optimized measurement (ROM]) in the parasternal long-axis view and an optimized still image of the MV obtained from the same cine loop [specialist-optimized image (SOI)]. Each still image and associated cine loop was quadruplicated and randomized to determine intra- and inter-rater agreement and quantify the impact of zoom on AMVL measurement. RESULTS: Specialist-optimized image without zoom reflected the highest degree of agreement in both cohorts with an ICC of 0.29 and 0.46. The agreement in ROM images without zoom was ICC of 0.23 and 0.45. The addition of zoom to SOI decreased agreement further to an ICC of 0.20 and 0.36. The setting associated with the poorest agreement profile was ROI with zoom with an ICC of 0.13 and 0.34, respectively. The intra-rater agreement between readers in both cohorts was moderate across all settings with an ICC ranging between 0.64 and 0.86. CONCLUSIONS: The WHF AMVL measurement is only moderately repeatable within readers and demonstrates poor reproducibility that was not improved by the addition of a zoom-optimized protocol. Given our study findings, we cannot advocate the current WHF AMVL measurement as a reliable assessment for RHD.
No takes yet. Share an insight, caveat, or question.
Hunter et al. (2020) conducted an observational in Previous acute rheumatic fever (n=16). World Heart Federation anterior mitral valve leaflet measurement vs. Different image optimization and zoom settings was evaluated on Inter-rater and intra-rater agreement (Intraclass Correlation Coefficient) (ICC 0.29 and 0.46 (highest agreement)). The World Heart Federation anterior mitral valve leaflet measurement demonstrated poor inter-rater reproducibility (highest ICC 0.29 and 0.46) that was not improved by zoom-optimized protocols.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: