This is the authors' abstract. We don't add key points for this paper.
We report on an electrical microfluidic pressure gauge. A polydimethylsiloxane microvalve closes at a characteristic applied pressure determined by the material's properties and the valve's dimensions. Hence, when the same pressure is applied to all valves of a heterogeneous valve array, some valves close while others remain open. The state of the array is combined with knowledge of the respective characteristic closing pressures of the individual valves to yield an estimate of the applied pressure. The state of each valve is obtained by electrical measurements, since the electrical resistance of the respective underlying fluid-filled channel increases by at least two orders of magnitude as the valve closes and its insulating elastomer material interrupts the electrical circuit. The overall system functions as a pressure gauge with electrical readout. This device would be a critical component in active pressure-regulation loops in future integrated microfluidic systems.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Kartalov et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: