Key result
Ocular pulse amplitude measured by dynamic contour tonometry identifies severe cardiovascular disease in 3 patients.
Why the study?
The potential of ocular pulse amplitude measured by dynamic contour tonometry as a noninvasive screening tool for severe cardiovascular disease is not established.
Can dynamic contour tonometry and ocular pulse amplitude help detect severe cardiovascular pathologies?
Case Report (n=3)
Can dynamic contour tonometry and ocular pulse amplitude help detect severe cardiovascular pathologies?
Ocular pulse amplitude measured by dynamic contour tonometry may serve as a noninvasive screening tool for detecting severe underlying cardiovascular diseases.
May prompt consideration in select unexplained cases; hypothesis-generating for dynamic contour tonometry as a cardiovascular detector.
We demonstrate the close relationship between a conspicuous ocular pulse amplitude and severe underlying cardiovascular disease. Two otherwise symptom-free glaucoma patients without any previously diagnosed underlying cardiovascular pathology but with a conspicuous ocular pulse amplitude and who underwent routine examinations in our glaucoma department were referred to the appropriate specialty for further diagnostic procedures. In both patients, the diagnosis of a tachyarrhythmia was made as suspected on dynamic contour tonometry measurements. In addition to medical treatment, one patient underwent electric cardioversion and the second patient was scheduled for pacemaker implantation. A third patient with an unexpected high ocular pulse amplitude despite severe cardiovascular pathology underwent major surgery due to an aortic aneurysm. Carotid stenosis was diagnosed due to side differences in ocular pulse amplitude as well. Ocular pulse amplitude might be a noninvasive and affordable screening tool and could be used to detect severe cardiovascular disease. A prospective study including a larger number of patients is needed to prove this hypothesis.
No takes yet. Share an insight, caveat, or question.
Bertelmann et al. (2014) conducted a case report in Glaucoma and suspected cardiovascular disease (n=3). Dynamic contour tonometry and ocular pulse amplitude was evaluated on Detection of severe cardiovascular disease. Conspicuous ocular pulse amplitude measured by dynamic contour tonometry successfully identified severe underlying cardiovascular diseases in three patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: