This letter presents a novel design and implementation of a transmission-line negative group delay (NGD) network with improved signal attenuation (SA). Theoretical analysis shows that the NGD time can be controlled by characteristic impedance of the coupled line, coupling coefficients, and resistor, respectively. The low SA characteristic in the proposed structure is obtained due to high characteristic impedance of the coupled line. To validate the proposed structure, the transmission-line NGD networks are fabricated and measured at 2.14 GHz. From the experiment, the differential-phase group delay (GD) time and SA for a single stage are -6.16 ns and 8.65 dB over bandwidth of 15 MHz, respectively. For bandwidth enhancement, two-stage NGD networks with slightly different center frequencies are designed and fabricated, where GD of -7.48 ±0.84 ns and SA of 17.45 dB were obtained over a bandwidth of 28 MHz.