Key result
Percutaneous ASD closure is linked to decreased atrial electromechanical delay and altered LA mechanics.
Why the study?
The early and mid-term effects of percutaneous closure of secundum ASD on atrial electromechanical delay and left atrial mechanical functions were not well characterized.
Does percutaneous closure of secundum ASD improve atrial electromechanical delay and left atrial mechanical functions in adult patients?
Observational (n=41)
Does percutaneous closure of secundum ASD improve atrial electromechanical delay and left atrial mechanical functions in adult patients?
Percutaneous closure of secundum ASD improves left atrial conduit function and decreases atrial electromechanical delay in the mid-term, although it impairs contractility functions early and mid-term.
Should not yet change ASD closure practice; leaves open long-term outcome implications of mixed atrial function changes.
AIMS: Atrial septal defect (ASD) is one of the most common congenital heart diseases in adults. We prospectively evaluated early and mid-term effects of the percutaneous closure of secundum ASD on atrial electromechanical delay (AEMD) and left atrial (LA) mechanical functions at the first day and sixth month in patients undergoing percutaneous closure. METHODS AND RESULTS: Forty-one patients were included in this study. Twenty-six (63.4%) of the 41 patients were female and the mean age was 41 ± 13 years. All the patients had echocardiographic examination before the procedure and at the first day and sixth month after the procedure. LA volumes (maximal, minimal, and presystolic) and EMD (lateral, septal, and tricuspid) were measured. Left and right intra- and inter-AEMD were not changed at the first day but both were significantly shorter at the sixth month. There was no change in the total emptying volume and fraction before and after the procedure. LA maximal, minimal, and pre-systolic volumes, active emptying volume, and fractions were decreased at the first day and at the sixth month compared with pre-procedural volumes. LA passive emptying volume, passive emptying fraction, and conduit volume were increased at the first day and at the sixth month compared with pre-procedural volumes. CONCLUSION: Our results revealed that there was no change in the LA mechanical reservoir functions, but improved conduit function and impaired contractility functions early and in the mid-term after percutaneous closure of ASD and decreased AEMD only in the mid-term.
No takes yet. Share an insight, caveat, or question.
Aslan et al. (2014) conducted an observational in Atrial septal defect (ASD) (n=41). Percutaneous closure of secundum ASD vs. Pre-procedural baseline was evaluated on Atrial electromechanical delay (AEMD) and left atrial (LA) mechanical functions. Percutaneous closure of secundum ASD improved left atrial conduit function and impaired contractility at 1 day and 6 months, and decreased atrial electromechanical delay at 6 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: