Key result
A novel ex vivo heart evaluation system successfully matched the maximal in vivo effect of adrenaline on cardiac output and blood pressures, maintaining normal blood gases after 2 hours.
Why the study?
A reliable ex vivo method to test whole heart function with selective investigation of right and left heart was needed.
Does a novel ex vivo system reliably replicate in vivo cardiac output and blood pressures in pig hearts?
Does a novel ex vivo system reliably replicate in vivo cardiac output and blood pressures in pig hearts?
A novel ex vivo heart evaluation system with parallel left and right circuits reliably replicates in vivo maximal hemodynamic responses to adrenaline in pig hearts.
Objectives. The aim was to demonstrate a reliable ex vivo method to test the function of the whole heart. Design. Pigs of varying sizes (44–80 kg) were exposed to dose response of adrenaline. Blood pressures and cardiac output were measured. The explanted hearts were tested in a novel ex vivo system to see if we could replicate the in vivo values at maximal adrenaline stimulation. The perfusion solution was STEEN Solution™ with erythrocytes and continuous infusion of essential drugs. In contrast to normal body circulation which is sequential, the heart evaluation system is divided into left and right heart circuits which are operating in parallel, making it possible to test the right and left heart individually or as a whole. The system provides coronary flow measurements. The nonlinear dynamic resistances are constructed to stabilize systolic and diastolic pressures in a broad range and independently from cardiac output. It is important for the functional evaluation to avoid pumping help for the heart; therefore, atrial vortexes are constructed to minimize pump flow directionality and energy from entering atria. Results. Ex vivo evaluation was able to match the maximal in vivo effect of adrenaline on cardiac output and blood pressures. After 2 h of evaluation, the blood gases and lactate were normal and free haemoglobin was zero. Autopsy of the hearts showed no macroscopic pathology. Conclusions. The system is able to give a reliable functional evaluation of the heart ex vivo.
No takes yet. Share an insight, caveat, or question.
Steen et al. (2024) studied Ex vivo heart evaluation. Novel ex vivo heart evaluation system vs. In vivo values at maximal adrenaline stimulation was evaluated on Cardiac output and blood pressures matching maximal in vivo effect of adrenaline. A novel ex vivo heart evaluation system successfully matched the maximal in vivo effect of adrenaline on cardiac output and blood pressures, maintaining normal blood gases after 2 hours.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: