Key result
Scoring systems (APACHE II, POSSUM, SAPS II) showed no significant correlation between predicted and observed mortalities following abdominal aortic aneurysm repair.
Why the study?
Scoring systems are used to predict mortality after abdominal aortic aneurysm repair, but their accuracy in this patient group is uncertain.
Do scoring systems (APACHE II, POSSUM, SAPS II) accurately predict mortality in patients undergoing abdominal aortic aneurysm repair?
Observational (n=152)
Do scoring systems (APACHE II, POSSUM, SAPS II) accurately predict mortality in patients undergoing abdominal aortic aneurysm repair?
Answers are grounded in this paper and cite their sources.
Common intensive care and surgical scoring systems are inaccurate for predicting individual mortality after abdominal aortic aneurysm repair and should not be used to guide individual treatment or prognosis.
BACKGROUND: Abdominal aortic aneurysm repair is associated with significant morbidity and mortality. This study aims to evaluate the efficiency of scoring systems in a group of patients undergoing abdominal aortic aneurysm repair. METHODS: A prospective study of 152 patients undergoing aneurysm repair was conducted. Each patient was scored according to the Acute Physiology and Chronic Health Evaluation II, Physiological and Operative Severity Score for the enUmeration of Mortality and Morbidity and Simplified Acute Physiology Score II systems. The predicted mortality for each patient was calculated. Chi(2) analysis was carried out to determine the accuracy of mortality predictions. Receiver-operator curves were drawn to compare scoring systems in terms of sensitivity and specificity. RESULTS: In the elective aneurysm repair group, all scoring systems tended to overestimate mortality. Receiver-operator curves showed inaccuracies in identifying patients who were at high risk from surgery. In contrast, predicted mortalities underestimated the true death rate among the ruptured aneurysm group. Receiver-operator curves showed better efficiency of scoring systems in the ruptured aneurysm group than in the elective repair group. There was no significant correlation between predicted and observed mortalities in either group. CONCLUSION: In this study, all systems showed significant errors when predicting mortality. Therefore, although useful as an audit tool, scoring systems should not be used on an individual basis to guide treatment and assess prognosis after surgery.
No takes yet. Share an insight, caveat, or question.
Sandford et al. (2007) conducted an observational in Abdominal aortic aneurysm (n=152). Scoring systems (APACHE II, POSSUM, SAPS II) was evaluated on Mortality. Scoring systems (APACHE II, POSSUM, SAPS II) showed no significant correlation between predicted and observed mortalities following abdominal aortic aneurysm repair.
Synapse has enriched 10 related papers. Consider them for comparative context: