Key result
Transjugular leadless pacemaker achieves successful pacing in a 4-year-old child with severe metal allergy.
Why the study?
Leadless pacemakers have limited clinical application in low-weight pediatric patients with metal allergies, and no established implantation protocols exist for this population.
Case Report (n=1)
No
Transjugular leadless pacemaker implantation offers a feasible alternative for low-weight pediatric patients with metal allergies and exhausted conventional venous access.
Answers are grounded in this paper and cite their sources.
May offer an alternative in select pediatric metal allergy cases; hypothesis-generating and requires prospective validation before adoption.
BACKGROUND: Leadless pacemakers (L-PMs) have limited clinical application in low-weight young pediatric patients. Conventional transvenous pacemakers carry infection/allergy risks, with no established L-PM implantation protocols for metal-allergic pediatric populations. CASE SUMMARY: A 4-year-old child with third-degree atrioventricular block had previously undergone 3 failed transvenous pacemaker implantations, each complicated by poor incisional healing and skin ulceration of the subcutaneous pockets. Patch testing confirmed metal allergy. A leadless single-chamber pacemaker (Micra VR, Medtronic) was successfully implanted via the right internal jugular vein. DISCUSSION: Pediatric metal allergy to pacemaker casings is rare, and conventional pacing is unfeasible in such cases. Literature on transjugular L-PM implantation in low-weight children with nickel-titanium allergy is scarce, with no standardized venous access or procedural approaches reported. TAKE-HOME MESSAGE: Transjugular L-PM implantation is a viable alternative for low-weight pediatric patients with pacemaker metal allergy and failed conventional pacing, providing a critical technical pathway for this high-risk population.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) conducted a case report in Third-degree atrioventricular block and pacemaker metal allergy (n=1). Transjugular leadless pacemaker (Micra VR) was evaluated on Successful implantation and pacing. Transjugular leadless pacemaker implantation was successfully performed in a 4-year-old child with pacemaker metal allergy and failed conventional pacing.