Why the study?
Potential regional disparities in characteristics, perceptions, and information levels of ICD recipients across Europe were not well characterized.
Are there regional disparities in patient perceptions and satisfaction after ICD implantation in Europe?
Cross-Sectional (n=1,809)
Yes
Are there regional disparities in patient perceptions and satisfaction after ICD implantation in Europe?
Absolute Event Rate: 52.9% vs 46.6%
p-value: p=0.047
There are significant regional disparities in patient satisfaction and perceived quality of information provided after ICD implantation across Europe, highlighting the need for tailored patient education and support strategies.
Regional disparities in post-ICD satisfaction should not yet change practice; leaves open prospective validation of tailored education strategies.
AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted.
No takes yet. Share an insight, caveat, or question.
Januszkiewicz et al. (2023) conducted a cross-sectional in Implantable cardioverter-defibrillator (ICD) recipients (n=1,809). Region of residence (Central/Eastern Europe) vs. Western and Southern Europe was evaluated on Increased satisfaction after ICD placement (p=0.047).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: