Key result
Mitral valve ring annuloplasty linked to ~175% higher coaptation length index, correlating with less residual MR.
Why the study?
Information on mitral valve leaflet morphology after mitral valve reconstruction is limited in clinical settings.
Does mitral valve ring annuloplasty improve mitral valve leaflet morphology and reduce residual mitral regurgitation in patients with mitral regurgitation?
Observational (n=36)
Does mitral valve ring annuloplasty improve mitral valve leaflet morphology and reduce residual mitral regurgitation in patients with mitral regurgitation?
Mitral valve ring annuloplasty increases the coaptation length index, which correlates negatively with residual mitral regurgitation.
Answers are grounded in this paper and cite their sources.
May support annuloplasty to improve coaptation and lessen residual MR; leaves open need for prospective validation.
BACKGROUND: In clinical settings, information on morphology of mitral valve leaflet after mitral valve reconstruction is limited. METHODS: Between January 1996 and June 2000, 36 underwent mitral valve repair for mitral regurgitation (MR). The etiology of mitral insufficiency was prolapse, dilated annulus, and ischemic. Ring annuloplasty was performed in all cases. Mitral valve short-axis dimension (MVd), vertical distance between annular line and closing point (Vd), coaptation length (CL), coaptation length index (CL/MVd) were measured by the two-dimensional transesophageal echocardiography for the present 11 cases. RESULTS: In 11 cases, residual MR, using a scale from 0 to 4, was 0 in 5 patients, 1 in 4 patients, 2 in 2 patients whose etiology of regurgitation was cardiomyopathy. MVd and Vd decreased significantly (38.7 +/- 6.2 to 27.0 +/- 5.6 mm, 10.1 +/- 7.7 to 6.5 +/- 4.6 mm, respectively). CL and CLI increased significantly (6.4 +/- 2.4 to 11.6 +/- 4.6 mm, 0.16 +/- 0.06 to 0.44 +/- 0.21, respectively). Among those index, only CLI have a statistically significant negative correlation with the degree of residual MR. CONCLUSION: The mitral valve ring annuloplasty produce the morphologic change of mitral apparatus, especially the increase of CLI, which may be one of the main factors in regulation of regurgitation.
No takes yet. Share an insight, caveat, or question.
Yamauchi et al. (2004) conducted an observational in Mitral regurgitation (n=36). Mitral valve ring annuloplasty vs. Pre-operative baseline was evaluated on Coaptation length index (CLI). Mitral valve ring annuloplasty increased the coaptation length index, which had a significant negative correlation with the degree of residual mitral regurgitation.