Key result
Healthy Dutch echocardiographic dimensions and volumes consistently exceed guidelines while functional parameters match recommendations.
Why the study?
Normative echocardiographic data from current guidelines may not be applicable to the Dutch population due to observed higher values in clinical practice.
Cross-Sectional (n=147)
No
Echocardiographic linear and volumetric parameters in a healthy Dutch population are consistently higher than current guideline recommendations, suggesting the need for population-specific reference values.
Dutch echo norms may better fit local physiology than guidelines; leaves open whether population-specific references should replace standards pending validation.
AIM: For accurate interpretation of echocardiographic measurements normative data are required, which are provided by guidelines. For this article, the hypothesis was that these cannot be extrapolated to the Dutch population, since in Dutch clinical practice often higher values are found, which may not be pathological but physiological. Therefore this study aimed to 1) obtain and propose normative values for cardiac chamber quantification in a healthy Dutch population and 2) determine influences of baseline characteristics on these measurements. METHODS: Prospectively recruited healthy subjects, aged 20-72 years (at least 28 subjects per age decade, equally distributed for gender) underwent physical examination and 2D and 3D echocardiography. Both ventricles and atria were assessed and volumes were calculated. RESULTS: 147 subjects were included (age 44 ± 14 years, 50% female). Overall, feasibility was good for both linear and volumetric measurements. Linear and volumetric parameters were consistently higher than current guidelines recommend, while functional parameters were in line with the guidelines. This was more so in the older population. 3D volumes were higher than 2D volumes. Gender dependency was seen in all body surface area (BSA) corrected volumes and with increasing age, ejection fractions decreased. CONCLUSION: This study provides 2D and 3D echocardiographic reference ranges for both ventricles and atria derived from a healthy Dutch population. BSA indexed volumes are gender-dependent, age did not influence ventricular volumes and a rise in blood pressure was independently associated with increased right ventricular volumes. The higher volumes found may be indicative for the Dutch population being the tallest in the world.
No takes yet. Share an insight, caveat, or question.
Grootel et al. (2017) conducted a cross-sectional in Healthy volunteers (n=147). Dutch population characteristics (height/ethnicity) vs. Current guideline upper limits of normal was evaluated on Echocardiographic chamber dimensions and volumes compared to guidelines. Echocardiographic linear and volumetric parameters in a healthy Dutch population consistently exceeded current guideline recommendations, whereas functional parameters were in line with guidelines.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: