Answers are grounded in this paper and cite their sources.
PurposeThe aim of this study was to evaluate stress distribution around short implants with different diameters in maxillary bilateral distal extension bases.Materials and methodsStrain gauge technology was used for strain analysis for two different diameters of short implant. On the seven epoxy resin models, two different short implant diameters were used as follow: Group A: on one side of the model, two implants with 4.8 mm diameter and 5 mm length were used. One implant was placed in the second premolar region and the other was placed in the second molar region. For group B: implants with 6.2 mm diameter and 5 mm length were used. For both groups, ceramometal screw retained fixed partial dentures were constructed on the transmucosal abutments. Stresses were measured at the buccal and lingual side of each implant under 200 N vertical load and 40 N oblique load. Data were collected, tabulated, and statistically analyzed.ResultsThe present study revealed that minimum stresses were induced on vertical and oblique loads around the short implants that had wider diameters.ConclusionWithin the limitation of this study, it could be concluded that, using short implants with wider diameter is a reliable method for restoring the distal extension bases.
No takes yet. Share an insight, caveat, or question.
Azab et al. (2020) studied this question.