Key result
Contact sensing guided high-intensity ultrasound achieves 100% lesion efficiency versus standard ultrasound in swine.
Why the study?
High-intensity ultrasound ablation has been limited by directional transducer orientation, resulting in inconsistent myocardial targeting with low lesion efficiency and transmurality.
Contact sensing may enhance high-intensity ultrasound lesion efficiency; extends preclinical data but leaves clinical translation open.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Morris et al. (2026) studied Ventricular tachycardia and hypertrophic cardiomyopathy (swine model) (n=23). Contact sensing guided high-intensity ultrasound (CSG-HIU) vs. Standard high-intensity ultrasound (Std-HIU) was evaluated on Lesion efficiency (p=0.007). Contact sensing guided high-intensity ultrasound improved lesion efficiency compared to standard ultrasound (100% vs 50%, p=0.007) in a terminal swine model.