Key result
Newborns with HLHS show ~25% larger tricuspid valve circumferences and reduced anterior strain versus controls.
Why the study?
It is currently unknown how the tricuspid valve annulus mechanics and geometry are associated with tricuspid regurgitation in newborns with hypoplastic left heart syndrome.
Observational
4D echocardiography reveals significant geometric enlargement and reduced strain in the tricuspid valve annulus of newborns with HLHS compared to healthy controls.
May link TV annulus mechanics to TR in HLHS; hypothesis-generating and requires prospective validation before clinical use.
Objective: Hypoplastic left heart syndrome (HLHS) is a congenital disease characterized by an underdevelopment of the anatomical components inside the left heart. Approximately 30% of HLHS newborns will develop tricuspid regurgitation (TR), and it is currently unknown how the valve annulus mechanics and geometry are associated with regurgitation. Thus, we present an engineering mechanics-based analysis approach to quantify the mechanics and geometry of the HLHS-afflicted tricuspid valve (TV), using 4-dimensional echocardiograms. Methods: =4) had their tricuspid valves imaged, and the data was imported to the 3D Slicer. The annular curves were defined at five points in the cardiac cycle. The geometry and deformation (strain) of the TV annulus were calculated to elucidate the mechanics of this critical structure, and compare them between HLHS and normal neonates. Results: For the annular geometry, HLHS-afflicted newborns had significantly larger annular circumferences (20-30%) and anterior-posterior diameters (35-45%) than the healthy patients. From a biomechanics perspective, the HLHS patients had significantly smaller strains in the anterior segments (-0.1±2.6%) during end diastolic and end isovolumetric relaxation (1.7±3.0%) compared to the healthy counterparts (-13.3±2.9% and 6.8±0.9%, respectively). Conclusions: The image-based analysis in this study may provide novel insights into the geometric and mechanistic differences in the TV annulus between healthy and HLHS newborns. Future longitudinal studies of the biomechanics of TV annulus and other subvalvular structures may inform our understanding of the initiation and development of TR and the design of optimal repairs in this challenging population.
No takes yet. Share an insight, caveat, or question.
Ross et al. (2022) conducted an observational in Hypoplastic left heart syndrome (HLHS). Hypoplastic left heart syndrome vs. Healthy neonates was evaluated on Tricuspid valve annulus geometry and deformation (strain). Newborns with hypoplastic left heart syndrome had significantly larger tricuspid valve annular circumferences (20-30%) and smaller anterior segment strains (-0.1% vs -13.3%) than healthy neonates.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: