This paper presents a comparison between the transform based proximity correction method and the GHOST background equalization method. Both methods are presented and evaluated in general as well as for a specific test structure. Emphasis is placed upon the frequency domain characteristics of each approach. It is shown that the GHOST method, by itself, while successfully equalizing the background exposure without the use of extensive computation, lacks good high frequency characteristics. This limits the fidelity of the corrections for features in the range of 0.50–0.20 μm. The transform or Fourier precompensation method can handle such features but it requires some degree of computation and data compaction. Experimental results are presented along with corresponding computer generated simulations. It is found that a very accurate measurement of the e-beam point spread function is essential to make the transform method perform properly. A technique is presented to achieve such a measurement.