Key result
Pannus excision without prosthetic valve re-replacement preserves function but fails to prevent 8-year recurrence.
Why the study?
Recurrent pannus formation causing prosthetic aortic valve dysfunction presents management challenges regarding excision with or without valve re-replacement.
Case Report (n=1)
No
Isolated excision of a pannus without replacing a well-functioning prosthetic aortic valve may be associated with pannus recurrence, raising questions about optimal surgical management.
Answers are grounded in this paper and cite their sources.
Requires individualized surgical excision for aortic prosthetic pannus based on location; leaves open etiology and prevention strategies.
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.
No takes yet. Share an insight, caveat, or question.
Ahmad K. Darwazah (2012) conducted a case report in Prosthetic aortic valve dysfunction due to recurrent pannus formation (n=1). Surgical excision of pannus without valve re-replacement was evaluated on Valve function and pannus recurrence. Excision of a localized pannus without re-replacement of the prosthetic aortic valve preserved valve function but did not prevent recurrent pannus formation 8 years later.
Synapse has enriched 10 related papers. Consider them for comparative context: