Key result
Pacing dependency affects ~45% of CIED patients, linked to female sex and complete AV block.
Why the study?
Pacing dependency and its associated factors in patients with cardiac implanted electronic devices at the CNHU-HKM in Cotonou were not well characterized.
What is the prevalence and what are the factors associated with pacing dependency in patients with a cardiac implanted electronic device?
Cross-Sectional (n=111)
No
What is the prevalence and what are the factors associated with pacing dependency in patients with a cardiac implanted electronic device?
Pacing dependency is common (45.1%) among CIED outpatients and is associated with female gender, preoperative complete AV block, and recent implantation.
May inform risk-stratified CIED follow-up; cross-sectional data leaves causal links and practice change open.
Introduction: Pacing dependency is defined as the inadequacy or absence of intrinsic rhythm that can lead to bradycardia-related symptoms or cardiac arrest upon cessation of ventricular stimulation. The aim of the present work was to study it in a sample of patients followed at the CNHU-HKM in Cotonou. Method and patients: This was a descriptive, analytical cross-sectional study carried out at the University Cardiology Clinic of Cotonou from February 1 to August 1, 2023. It included an exhaustive sampling of all patients admitted as outpatients for follow-up of a cardiac implanted electronic device (CIED). The variables studied were the presence or absence of pacing dependency and the factors associated with it. Results: One hundred and eleven patients were included, aged 69.6 ± 13.7 years. The sex ratio was 0.91. The type of CIED was a pacemaker in 96.4% of patients. Complete atrioventricular block was the indication for pacemaker implantation in 76.6% of cases. On the electrocardiogram, 82% of patients had a paced rhythm. During the control by programmer, pacing dependency was found in 45.1% of cases. In multivariate analysis, female gender, preoperative complete atrioventricular block and less than 12 months of CIED wearing time were significantly associated with pacing dependency. Conclusion: This result is highly dependent on the criteria used to define pacing dependency. The associated factors identified have also been found by other authors. Other factors remain to be discovered in studies involving larger samples.
No takes yet. Share an insight, caveat, or question.
Sonou et al. (2025) conducted a cross-sectional in Cardiac implanted electronic device (CIED) (n=111). Cardiac implanted electronic device (CIED) was evaluated on Pacing dependency. Pacing dependency was present in 45.1% of patients with a cardiac implanted electronic device and was significantly associated with female gender, complete atrioventricular block, and device wearing time under 12 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: