Key result
Nonelutable LMWH stent coating cuts in-vitro platelet deposition ~95% vs uncoated controls.
Why the study?
Low-molecular weight heparin is widely used during PCI but a nonelutable LMWH stent coating for enhanced thromboresistance has not been developed.
Does a nonelutable low-molecular weight heparin stent coating improve thromboresistance compared to uncoated stents in an in-vitro model?
Does a nonelutable low-molecular weight heparin stent coating improve thromboresistance compared to uncoated stents in an in-vitro model?
A novel nonelutable LMWH coating on sirolimus-eluting stents significantly reduces platelet deposition in vitro, suggesting potential for reducing stent thrombosis risk.
Answers are grounded in this paper and cite their sources.
Supports development of thromboresistant stent coatings; leaves open in-vivo and clinical validation.
Low-molecular weight heparin (LMWH) has been widely used as a systemic anticoagulant during percutaneous coronary intervention. In this study, LMWH was covalently immobilized to the surface of a cobalt chromium reservoir-based sirolimus-eluting stent to create a nonelutable nanoscale coating for enhanced thromboresistance. Toludine-blue stained stents revealed uniform heparin coverage on all surfaces of the stent. Scanning electron microscopy of stent strut cross-sections showed identical coating thickness on all sides; while the thickness was determined to be 320 nm by a focus-ion beam system. Secondary ion mass spectrometry showed constant concentrations of O, N, and S atoms throughout the depth of the surface, confirming the uniformity of the heparin coating. The nonelutable nature of the coating was confirmed in a modified Factor Xa inhibition assay which showed the stent had an equivalent of 3-5 heparin units/cm(2), while no elutable heparin was detected in wash solutions. The antithrombin binding capacity of the immobilized heparin was determined to be 60-80 pmol/cm(2) in an antithrombin uptake assay. The enhanced thromboresistance of the heparin coating was demonstrated in an in-vitro bovine blood flow loop which showed minimal visual thrombus accumulation and 95% reduction in platelet deposition compared to uncoated control stents. Drug-eluting stents with such nonelutable LMWH coating would represent a significant advance in the treatment of patients with complex lesions who are at increased risk of developing stent thrombosis.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2012) studied this question. Nonelutable low-molecular weight heparin (LMWH) stent coating vs. Uncoated control stents was evaluated on Platelet deposition in an in-vitro bovine blood flow loop (95% reduction). A nonelutable low-molecular weight heparin stent coating demonstrated a 95% reduction in platelet deposition compared to uncoated control stents in an in-vitro bovine blood flow loop.
Synapse has enriched 10 related papers. Consider them for comparative context: